Port connections
Type 2000
Threaded port:
NPT 3/8 to NPT 2 1/2
(G upon request)
Weld end connection:
-to ISO 4200
-to DIN 11850 R2
-OD tube (U. S.)
Pressure surge test to DIN 1988, Part 2
In order to meet the pressure surge test requirements of DIN 1988 Part 2,
the exhaust air must be vented through a restrictor having a maximum diameter
of 1 mm.
The flow restriction options are as follows:
•
Integrated construction of a restrictor or a one-way flow restrictor directly
in the pneumatic actuator.
•
Restrictor in the exhaust air port of a 4-way pilot valve.
•
Restrictor or one-way flow restrictor directly at the outlet of a
3-way pilot valve.
Bürkert offers the appropriate valves for this purpose.
10 - 2000/2002
Typ 2002
Angle-seat valve
NPT 3/8 to NPT 2 1/2
(G upon request))
1/2" - 2"
Globe valve
G 1/2 to G 2
(NPT is not available)
not available