User Instruction

Connection
1. Open the station door and start the exhaust extraction fan (as an alternative
the fan can be connected to an automatic start/stop system).
2. Reverse the vehicle
in so that the exhaust
pipe is just outside the
station door.
Manual disconnec-
tion from the anchor
plate is possible with a
switch on the electro-
magnet unit.
Disconnection
1. Make sure the extraction hose is connected to the exhaust
pipe and that it is firmly fastened to the anchor plate on the
vehicle's side.
2. Start the fan and open the station door. Drive the vehicle
straight out from the garage with a maximum speed of 15 km/h
(10 mph). The hose automatically disconnects when the vehicle
is driven out.
If the magnet does not disconnect as it should, it will be pulled off
the anchor plate by the hose without damage to the system. This
may cause the nozzle to sway more than normally.
Approx. 800 N (176 lbs) is required to pull the magnet off the
anchor plate.
The flexible hose can withstand 150 °C (300 °F) for con-
tinuous running and 180°C (355 °F) for short periods.
Use at higher temperatures will shorten the life of the product.
Therefore, avoid tasks that require extended periods
of continous running which will generate high exhaust
temperatures.
MagnaTrack S
3. Locate the nozzle
of the flexible hose
on the exhaust pipe.
Fasten the electro-
magnetic unit onto
the anchor plate
located on the side of
the vehicle.
Fitting the standard
or HB-nozzle.
max. 1 m (3 ft)
4. Reverse the vehicle into
its parking space. The hose
should always be con-
nected to the exhaust pipe
while the vehicle is parked
in the station.
Alternative fitting of
HB-nozzle.
WARNING!
Risk of personal injuries and/or product damage.
The system must not be used for other purposes than
extracting exhaust fumes.
Do not extract hot, burning or ignited material or sub-
stances that might react with parts or materials from
the suction system.
The system must only be used in combination with the
anchor plate which should be mounted on the vehicle.
The system must not be used when working on the
vehicle´s fuel system, when recharging the batteries
or whenever there is a risk for inflammable dust or
explosive gases.
The system must be disconnected and must not be
exposed to water when washing the vehicle.
The system is designed for use only in the direction of
the length of the rail.
Check that there is enough suction capacity in the
exhaust hose before it is connected to the vehicle ex-
haust pipe. If needed, check the fan impeller rotation
direction and/or damper function.
Check that the nozzle is correctly fitted to the exhaust
pipe after the vehicle has been moved.
Check that the hose or nozzle will not snag on any
protruding parts on the vehicle.
GB