Saeco DA 7P PLUS Mode D'emploi Et D'entretien page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
8.7 Assembly of the NRI G26 coin changer
8.8 Connecting the Personal Computer to the Machine
G 26 model serial port
8.9 Inserting labels
30
Only an executive type coiner can be used with this equipment.
• Assemble the metal cable stopper supplied with the equipment.
• Pass the coiner cables trough the cable stopper, making sure they do not block the coin
inlet or prevent the correct operation of the coiner release lever (Fig. 19).
• Fasten the coiner to the relevant plate with the three pins already fitted on the plate.
Keep the coiner release lever pressed to make the coiner fitting easier (Fig. 20).
• Connect the 2 coiner cables supplied with connectors to the cables already fitted on
the machine.
Fig. 19
The third coiner cable with serial connection is not currently used. When the coiner has
been assembled, program sale prices according to the procedure previously described
above for the G13 coiner.
The coiner channels have been pre-set for coin values. The user does not need to program
these values.
This coiner is automatically programmed in the MULTI-PRODUCT dispensing
function, as previously described (menu "U").
Fig. 20
For further information relevant to the coiner, see the instruction manual of the coiner.
G 13 model serial port
Fig. 21
Separate product labels along the perforations. Stick the adhesive price labels on the
product labels. Slide labels into their proper positions. Remove frame knobs, lift the
transparent panel (Fig. 22) and insert the graphics. Instructions to operate the
equipment should be applied below the graphic.
Fig. 22
(Fig. 21)
Fig. 21
Please note: Special software is required.
To connect a PC to the machine, use a 3-
wire (inverting) serial connection cable,
equipped with two 9-pole connectors.
Make sure both the machine and the PC are
off, then carry out the cable connection,
through the serial port 30, shown in Fig.
21.
Start the machine first and then the PC; this
will establish a connection and enable real-
time data exchange.

Publicité

Table des Matières
loading

Table des Matières