Characteristics
®
BADU
90,
®
BADU
90-AK*
50 Hz, n = 2840 min
applicable for water
of 20°C
KL 90.80.001
Technical data at 50 Hz
Inlet/outlet D(mm)
Recommended inlet/outlet pipe, PVC pipe, d
Power input P
(kW)
1
1)
Power output P
(kW
)
2
Rated current (A)
Sound pressure Level in 1 meter distance
Lpa (1m)/dB(A)
Acoustic capacity
Lwa (1m)/dB(A)
Power input P
(kW)
1
1)
Power output P
(kW)
2
Rated current (A)
Sound pressure Level in 1 meter distance
Lpa (1m)/dB(A)
Acoustic capacity
Lwa (1m)/dB(A)
Weight (kg)
Weight (kg)
Type of motor enclosure
Thermal class
Motor speed approx. (rpm)
Max. water temperature (°C)
Max. casing interior pressure (bar) 2,5
* BADU 90/25-AK to BADU 90/48-AK pumps are available with 3 phase motors.
52
-1
BADU
1~ 230 V
1~ 230 V
1~ 230 V
2)
1~ 230 V
1~ 230 V
3~ Y/Δ 400/230 V
3~ Y/Δ 400/230 V
3~ Y/Δ 400/230 V
2)
3~ Y/Δ 400/230 V
3~ Y/Δ 400/230 V
1~
3~
1)
For standard voltage according to IEC 60038
IP X4
and DIN EN 60034 (Euro-voltage).
F
Suitable for continuous operation at 1~ 220-240 V
2840
60
Tolerances ± 5%.
GS-tested pumps according to EN 60335-1.
2)
Measured with a phonometer according to DIN 45635.
Flow rate Q (m
3
/h)
90/25
90/30
75/75
75/75
75/75
75/75
1,85
2,00
1)
1)
1,30
1,50
7,90
8,80
64,3
66.0
72
74
1,65
1,90
1)
1)
1,30
1,50
3,00/5,20 3,30/5,70
65,8
67,4
74
75
23,6
23,6
21,0
21,0
90/40
90/48
90/90
90/90
90/90
100/100
2,90
3,45
1)
1)
2,20
2,60
13,00
15,00
72,2
72,8
80
81
2,70
3,30
1)
1)
2,20
2,60
4,60/8,00
5,60/9,70
69,0
69,7
77
78
26,5
34,0
25,0
26,0
3~ Y/Δ 380-420 V / 220-240 V