12 Technical Data

PURITY Quell ST filter system
Operating pressure
Operating/water temperature
Ambient tempera-
ture during
Flow rate with 1 bar pressure loss
Nominal flow in accordance with standard
Pressure loss at nominal flow
Empty filter cartridge volume
Weight (dry/wet)
Dimensions
Operating position
Inlet connection
Outlet connection
* with ACS Technology
Comparable capacity according to DIN 18879-1:2007
The comparable capacity is a standardised indicator to facilitate comparison of different filters. The
comparable capacity is determined under extreme conditions. The usable capacity in practical opera-
tion is higher than the comparable capacity and may vary greatly depending on the usage conditions.
PURITY 450 Quell ST
PURITY 600 Quell ST
PURITY 1200 Quell ST
EN
36
PURITY 450 Quell ST
MAE*
operation
storage
300 l/h
60 l/h
0.12 bar
249 mm/222 mm/408 mm 249 mm/222 mm/520 mm 288 mm/255 mm/550 mm
System Tested and Certified
by NSF International against
NSF/ANSI Standard 42 for the
reduction of Chlorine taste and
odor and against CSA B483.1.
PURITY 600 Quell ST
Distributor
MAE*
head
2 bar – max. 6.9 bar
4°C to 30°C
10°C to 40°C
–20°C to 50°C
350 l/h
300 l/h
60 l/h
120 l/h
0.08 bar
0.36 bar
3.9 l
10 kg/12 kg
Vertically or horizontally
Comparable capacity according to DIN 18879-1:2007
2240 litres
4420 litres
7253 litres
PURITY 1200 Quell ST
Distributor
MAE*
head
350 l/h
300 l/h
120 l/h
120 l/h
0.27 bar
0.32 bar
5.8 l
12 kg/15 kg
18 kg/24 kg
G 1"
G 3/4"
Distributor
head
350 l/h
120 l/h
0.24 bar
10.9 l

Publicité

Table des Matières
loading