Carbonate Hardness
in °dH (°KH)
25
28
31
35
Note: The capacity limits refer to average utilisation of the terminal equipment, do not contain any
filter flushing and cleaning cycles and depend on local water quality, flow, mains pressure and flow
continuity.
8 Repair
Regularly check the filter system for leaks. Regularly check the hoses for kinks. Bent hoses must be
replaced.
The complete filter system must be replaced in rotation after a maximum of ten years.
The hoses must be replaced in rotation after a maximum of five years.
Caution: Prior to changing, read the Technical Data (Chapter 12) and the Operating and Safety
!
Information (Chapter 3).
Regularly clean the outside of the filter system with a soft, damp cloth.
Caution: Do not use any substances incompatible with the material (Chapter 3.4) or abrasive
!
cleaning materials.
9 Query Mode
The following data can be queried in the query mode:

Production data

Briefly press button 1 x (< 1 second), the following message appears.
EN
Production year: Example 08 = 2008
Device number: consecutive
Battery useful life: Example 31/12/19 = The battery in the display unit will be exhausted on 31/12/19
and the complete filter system has reached its max. usage period.
32
By-pass setting
PURITY 450
10%
10%
10%
10%
ID Level
Serial Appliance Number
Filter capacity in litres
PURITY 600
1198
2047
1070
1828
966
1651
856
1462
Production Year
Battery Service Life
PURITY 1200
3746
3344
3021
2676

Publicité