- Y ellow light: 90 % of the filter capacity has been used. R emember
to buy a new replacement filter cartridge.
- Red light: The filter cartridge needs to be changed.
E Reprogramming the BRITA Tap Cartridge Status
Indicator
If the maximum volume is reached or the cartridge has been used
for 12 months, the BRITA Tap Cartridge Status Indicator's LED will
start flashing red (only if BRITA lever is in the filtering position).
In this case the filter cartridge should be replaced (chapter 4). Once
the cartridge has been replaced the BRITA Tap Cartridge Status
Indicator has to be reset. For this purpose push the reset button
(fig. 5) of the Cartridge Status Indicator for three seconds until it
starts flashing green (for this step, you do not need to remove the
BRITA Tap Cartridge Status Indicator from the BRITA lever).
After replacing of the empty battery the commissioning should be
followed in accordance with section 3.2.

Technical data:

• Battery: 1x CR2032 (removable)
• lifetime of battery: app. 2 years
!
Do not immerse Cartridge Status Indicator in water
3.3
Step 3: Installing the BRITA Tap
To install the BRITA Tap, firstly ensure you have all the components
required.
Please, make sure that there is enough room and access
!
under the sink to allow for the installation of the filter head
and cartridge, and to connect the two supplied hoses.
1014662-002_GA_BRITA_Tap_CE.indb 7
WD 3020
1. B RITA Tap with 3 hoses
1.
2. B RITA Tap Cartridge Status Indicator
3. O -Ring
4. S hank
5. J oint (Is only necessary for installa-
tion of the dispenser if you directly
mount it onto your sink. If you
mount it onto your countertop-plate,
you do not necessarily need this
2.
part. It helps stabilizing the tap at
3.
your sink)
6. F lat Gasket
7 . F lange
4.
8. H ex nut
5.
6.
7.
8.
(fig. 6)
WD 3030/ WD 3040 and WD 3050
1. B RITA Tap (design may differ) with
3 hoses
2. B RITA Tap Cartridge Status Indicator
3. B ase
4. Shank
5. J oint (Is only necessary for installa-
tion of the dispenser if you directly
1.
mount it onto your sink. If you
mount it onto your countertop-plate,
2.
you do not necessarily need this
part. It helps stabilizing the tap at
3.
your sink)
6. F lat Gasket
7 . F lange
8. H ex nut
4.
5.
6.
7.
8.
(fig. 7)
7
ENGLISH
04.04.16 11:27

Publicité

Table des Matières
loading

Table des Matières