Warning
All work on the electrical installation must be carried out by a
qualified electricien.
Remove power supply plug only when the heater has entirely
cooled down
Malfunction
The space heater is connected up,
but:
the fan motor does not start, when the selector
switch is set to
= Heating
Overheat thermostat switches off
The space heater is connected up,
but:
The fan does not start, when the selctor
switch is set to
= Ventilation
8
Possible cause
a) No electrical supply
b) Defective selector switch
c) Motor or capacitor defective
d) Overheat thermostat is locked
e) Room thermostat falsely set
a) Defective overheat thermostat
b) Wrong laying of the warm air hose
(heat accumulation)
a) No electricity supply
b) Overheat thermostat is locked
c) Capacitor defective
Releasing
the overheat thermostat
- take off the protection cap by turning it to the left
- press the reset button with a suitable tool
- put on protection cap again

Malfunction and Remedy

Remedy
a) Check main switch and fuses
b) Replace selector switch the
operating instructions – if you do not
succed, call for customer serviced
c) Check motor or capacitor or replace if
necesary
d) Press reset button of overheat thermostat
e) Check room thermostat setting
a) Replace warm air thermostat
b) Laying of the warm air hose according to
the manual
a) Check main switch and fuses
b) Press overheat thermostat reset button
c) Check capacitor