Malfunction and remedy

Warning !
All work on the electrical installation must be carried
out by a qualified electrician.
Pull power supply plug only when the heater has cooled down
See also operating instructions for oil-/gasburner
Malfunction
The space heater ist connected up, but :
The heater does not start, when
the
selector switch is set to heating
The space heater is connected up and
switched on:
The oil burner starts and
immediately indicates a
malfunction
Overheat thermostat switches off
Temperature controller continually
switches off
Signal lamp at control box is on
The space heater is connected up,
but :
The fan does not start, when
the selector switch is set to
Ventilation
The heater is connected at electric
supply but does not operate
14
Possible Cause
a)
No electrical supply
b)
Defective selector switch
c)
Oil-/gasburner indicates a
malfunction
d)
Overheat thermostat is locked
e)
Room thermostat falsely set
a)
No oil in the tank
b)
Air in fuel circuit
c)
Oil filter clogged
d)
Stopcock closed
e)
Oil burner indicates a malfunction
again
a)
Defective temperature controller
a)
Temperature controller wrongly set
b)
Fan does not start
c)
Fuel flow rate too high
.
a) Burner indicates malfunction
a)
No electrical supply
b)
Defective fan
c)
Capacitor defective
a) No electrical supply
b) Fuse has interrupt
Remedy
a)
Check main switch and fuses
b)
Replace selector switch
c)
Reset oil-/gasburner if burner cuts
again, press reset button after 4 to
5 min.
See operating instruction for burner
d)
Press reset button of overheat
thermostat
e)
Check room thermostat setting
a)
Refill oil tank
b)
Check screwed connections of fuel
circuit for leaks
c)
Change filter element
d)
Open stopcock
e)
See operating instructions oil burner
a)
Replace warm air thermostat
a)
Check temperature controller
setting
b)
Check fan motor or capacitor or
replace it if necessary, eventual
check motor protector switch and
belt drive.
c)
Adjust fuel flow rate to given value.
a) See operation instruction burner
a)
Check main switch and fuses
b)
Replace fan
c)
Check capacitor
a) Check electrical supply
b) Replace fuses