Servicing And Cleaning; Cleaning Of Combustion Chamber; Cleaning Of Heat Exchanger Elements; Burner After Sales Service - Kroll HM100 Notice D'instruction

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

HM100

2.8 Servicing and Cleaning

2.8.1 Cleaning of combustion chamber

Starting maintenance work on mobile heating
unit
• Turn off electrical supply
• Set selector switch to „0"
• After the heater has cooled down, the main
switch must be turned off.
• Loosen clamping-ring on burner bracket.
Remove burner.
• Clean combustion chamber with brush and
vacuum cleaner through the opening.
2.8.2 Cleaning of heat exchanger ele-
ments
• Turn off electrical supply
• Set selector switch to „0"
• After the heater has cooled down, the main
power switch must be turned off.
• Upon of the relevant casing walls, the
cover of the heat exchanger, and the heat
exchanger seal, the individual pockets of
the heat exchanger have to be cleaned
using a brush and a vacuum cleaner

2.8.3 Burner after sales Service

Unscrew the 4 screws at up and down side, the 2
screws left and right at the blank cover, the push
the blank cover upside and remove it by pulling it
outside.
14

2.8.4 Servicing

According to § 9 of the reglementations for
heating plants it is demanded to let the plant
including the oil burner be serviced regularely in
order to assure a reliable and secure operation of
the device.
A service of the heater is neccessary once a year
We recommended to seal a service-contract with
an authorised entreprise
Burner- After- Sales Service
The burner should be checked and adjusted at
least annually.
On this occasion, the oil filter insert and the bur-
ner jet have to be replaced.
This work must only be made by the After Sales
Service or an authorized specialist firm.
After a failed start attempt, a control and if neces-
sary, a cleaning of the combustion chamber of
unburned heating oil must take place before the
reset button is pressed again.
Kroll recommends taking out a service contract.
The mobile heating unit must not be modified
or tampered with under any circumstances, and
repair work must be carried out by a specialist.
Main filter
Should be exchanged after 200 to 300 operating
hours.Replace the filter insert as soon as water
or dirt is detected in the filterglass
Fuel oil
Solenoid or water-contaminated fuel oil must be
renewed.
English