Code
Nom
Fonc.
C081 O input span calibration R/W Scale factor between the
C082 OI input span calibra-
tion
C085 Thermistor input tuning R/W Range is 0.0 to 200.0%
C086 [AM] terminal offset
tuning
C091 Debug mode enable
C101 Up/Down memory
mode
selection
C102 Reset selection
C141 Input A select for logic
output
C142 Input B select for logic
output
Fonctions de connexions intelligentes du Groupe "C"
R/W
Description
external frequency command
on terminals L – O (voltage
input) and the frequency
output, range is 0.0 to 200.0%
R/W Scale factor between the
external frequency command
on terminals L – OI (current
input) and the frequency
output, range is 0.0 to 200.0%
R/W Range is 0.0 to 10.0V
R
Displays debug parameters.
Two option codes:
00... Disable
01... Enable
R/W Controls speed setpoint for
the inverter after power cycle.
Two option codes:
00... Clear last frequency
(return to default frequency
F001)
01... Keep last frequency
adjusted by UP/DWN
R/W Determines response to Reset
input [RST].
Three option codes:
00... Cancel trip state at input
signal ON transition, stops
inverter if in Run Mode
01... Cancel trip state at signal
OFF transition, stops inverter
if in Run Mode
02... Cancel trip state at input
signal ON transition, no effect
if in Run Mode
R/W
See "Output Logic and
Timing" à la page 3–60
R/W
Variateur de fréquence SJ200-2
Données du réseau
Registre
hex
dec.
1141h 04417 0 to 2000
1142h 04418 0 to 2000
1144h 04420 0 to 2000
1145h 04421
1148h 04424
1149h 04425
114Ah 04426
1150h 04432 0, 1, 2, 3,
1151h 04433
B–41
Plage
Res.
0.1 %
0.1 %
0.1 %
0 to 100
0.1 V
0, 1
—
0, 1
—
0, 1, 2
—
—
4, 5, 6, 7,
8, 9