Set-up and assembly
nOTe!
86
ORBITALUM TOOLS GmbH D-78224 Singen www.orbitalum.com
X When first starting to process the pipe with the AVM, a low feed force level is recommended
which may be increased later. Higher levels result in a higher chip production and possibly
also in a higher wear of tools. The intelligent control system of the AVM monitors the
feed force continuously depending on the torque and the parameter settings.
X When cutting thin-walled pipes (wall thickness 3 - 5 mm), always start with level 1 and
select a higher level afterwards.
X Select the feed force level (L - 9) using the
standard values, see the table above).
GF 4, GF 6, RA 8, RA 12 (AVM/MVM)
/
buttons on the AVM display (for
[REV. 20190510] OC_GF_RA_BA_790142765_00__INH-02_EN