Steinberg Systems SBS-LW-2000A Manuel D'utilisation page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
2.
Press [ON/OFF] button –
display will show:
[0]F02
3.
Press [ON/OFF] button –
display will show: [2.0]F03
4.
Press [ON/OFF] button –
display will show:
[0.5]F04
5.
Press [ON/OFF] button –
display will show: [1.0]F05
6.
Press [ON/OFF] button –
display will show: [0]F06
EN
7.
Press [ON/OFF] button –
display will show:
[0] CAL
Press [UNITS] button –
display will show:
[1] CAL
8.
Press [ON/OFF] button –
display will show:
[200000]WET
9.
Press [ON/OFF] button –
display will show: [1]diV
10. Press [ON/OFF] button –
display will show:
[0.01]dEC
0/2/10/50
Zero returning
range when the scale
powers on:
2: If the weight
exceeds 2 percent of
the capacity before
the scale powers on,
the scale will not
work after turning on
2.0/0.0/0.3/0.5/0.7/1.0/1.5 Zero tracking range
0.5/0.7/1.0/1.5/2.0/0.0/0.3 Dynamic tracking
range
1.0/2.0/3.0/0.5
Dynamic tracing time
0/2/5/8
Auto-off after 2, 5 or
8 minutes of inactivity.
0/1
0 – after pressing the
ON/OFF button, scale
will exit the setup
with saving changes
1 – after pressing the
ON/OFF button scale
will proceed with the
remain of the setup
200000/300000/10000
Capacity of the scale.
/20000/30000/50000/
60000/100000/120000
/150000
1/2/5
Division 1, 2 or 5.
0.01/0.001/0.1
Changing the decimal
place of the displayed
weight value
14
11.
Press [ON/OFF] button
1/0
– display will show:
[1]LCP
12.
Press [ON/OFF] button
100000/120000/150000/
– display will show:
200000/300000/10000/
[100000]WE1
20000/30000/50000/60000
200000/300000/10000/
13.
Press [ON/OFF] button
– display will show:
20000/30000/50000/60000/
[200000]WE2
100000/120000/150000
14.
Press [ON/OFF] button
– display will show:
[---CODE---]SCL
15.
Press [ON/OFF] button
– display will show:
CALL1 and [0]CAL
16.
Put on the scale 1 kg
weight, display will show
[---CODE---] and PASS-1
and CALL-2
17.
Very quickly take out
the 1 kg weight from the
scale and put 2 kg
18.
Display will show PASS –
take out the weight from
the scale
19.
End of setup
ATTENTION: All the parameters of above advanced functions have been thoroughly
tested and set by the manufacturer. It is strongly recommended not to modify any of
these parameters, otherwise the scale may not work properly. However positions no 6,
9 and 10 (auto –off, division and decimal point) can be modified according to the needs.
REGULAR CONTROL OF THE DEVICE
Control regularly that the device doesn´t present any damage. If there is any damage,
please stop using the device. Please contact your customer service to solve the problem.
What to do in case of a problem?
Please contact your customer service and prepare following information:
Linear correction
switch:
0 is off, 1 is on.
Value of first
standard weight for
the calibration
Value of second
standard weight for
the calibration
-
-
-
-
-
-
-
-
-
-
-
-
16