Connecting The Luminaire To The 24 V Supply Voltage (Selv); Operation; Switch-On And Switch-Off; Dimming - Waldmann ALD Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENG
4.2
Connecting the luminaire
to the 24 V supply voltage
(SELV)
NOTICE
Material damage caused by wrong
mains voltage.
Damage or destruction of the luminaire.
X The connection must be made by a
trained skilled electrician only.
X Compare the mains voltage with
the nominal voltage and the fre-
quency specified on the rating
plate and make sure that they are
identical.
X Operate the luminaire at safety
extra low voltage (SELV) only.
2
No. Designation
1
DC +
2
DC -
3
Not connected
Tab. 1: Pin assignment.
NOTE: Please observe the pin assignment.
X Plug the plug into the socket provided
for this purpose.
16
5.

Operation

Fig. 5: Switch.
5.1
Switch­on and switch­off
X Press the switch, see Fig. 5.
5.2

Dimming

X Press the switch and keep it depressed,
see Fig. 5.
After about one second, the light will
change its brightness.
X To change the dimming direction, press
the switch again and keep it depressed.
This will save the set brightness. The
1
next time the light is switched on, the
brightness saved last will be set.
3
Operation

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mld 750/850/d

Table des Matières