4.2
Connecting the luminaire to
the supply voltage (SELV ver-
sion)
NOTE:This chapter applies only to lumi-
naires with the letter S in the model
number,forexampleMQAL24S.
To connect the luminaires, connecting
cables are recommended, which can be
found in theWaldmann range of acces-
sories.
NOTICE
Material damage caused by wrong
mains voltage.
Damageordestructionoftheluminaire.
X Theconnectionmustbemadebya
trainedskilledelectricianonly.
X Operatetheluminaireatsafety
extralowvoltage(SELV)only.
X Observethepinassignmentand
thesocketassignment.
X Useconnectingcablewithstrands
whichhaveaconductorcross-sec-
tionofatleast0.5mm².
NOTICE
Material damage caused by unsuita-
ble connecting cable and socket.
Degreeofprotectionoftheluminaireis
not guaranteed. Penetrating humidity
damagestheluminaire.
X Useconnectingcableandsocket
whichguaranteethedegreeofpro-
tectionoftheluminaire.
22
4
1
No. Designation
1
DC +
2
Notused
3
DC -
4
Functionalearth(FE)
Tab.4:MQALxxS pinassignment.
X Connect a suitable socket with the
A-codedplug.
4.3
Through-wiring
Luminaires with through-wiring can be
linkedtooneanotherviathepre-mounted
plug-in connection.These luminaires are
identified by the letter D in the model
number,forexampleMQAL24SD.
Tolinktheluminaires,connectingcablesare
recommended,whichcanbefoundinthe
Waldmannrangeofaccessories.
Formoreinformationontheaccessoriesof
thisluminaire,pleasevisittheWaldmann
homepageat:www.waldmann.com.
WARNING
Danger of death due to electric shock.
X Beforeestablishingordisconnect-
ingtheplug-inconnection,discon-
necttheluminairefromthepower
supply.
NOTE: In luminaires with through-wiring
connectedinseries,thetotalcurrentcon-
sumption must not exceed 12 A (AC)
respectively8 A (DC).
X Linktheluminaireswithasuitablecon-
nectingcable.
Connection