Fault diagnosis
The following simple checks may be performed by the operator
Trouble
Motors not working
Machine stalls during
operation.
Machine vibrates.
Vacuum motor
labouring.
* If the fuse blows several times, the machine should be checked by an authorises Service Agent
6
Set of Nylon brushes (standard brush)
Set of Tynex brushes (hard scrubbing brush)
Pack of 10 disposable paper bags
Brush retaining clips (2 required)
Escaclean chemical – 5 litres. 4 bottles per case
Reason
• Lack of voltage/electrical supply
• Current overload cut-out operated in
switch.
• Damaged brushes.
• Loose plug connection.
• Worn brushes
• Brushes incorrectly fitted.
• Brush cowl glide bars incorrectly set.
(Fig.1 / a).
• Dust bag full.
• Filter restricted.
Item
Remedy
• Check fuse *, supply cord, plug and
socket outlet
• Cut-out will reset automatically after a
few minutes. If cut-out operates
repeatedly check points below.
• Replace brushes.
• Check plug is fully inserted into mains
socket.
• Replace brushes.
• Refer to fitting instructions.
• Check height adjustment.
• Replace bag.
• Remove and clean.