13. TECHNICAL DATA
Display ..................................................2000 counts (characters)
Measuring rate ......................................approx. 2 measuring operations/second
Measuring method V/AC ......................arithmetic average
Measuring line length ...........................each approx. 90 cm
Measuring impedance .........................>1 MΩ (V-range)
Measuring socket distance ..................19 mm
Voltage supply .....................................9 V block batteries (NEDA 1604, 6F22 or same build)
Operating conditions ............................0 to 50 °C (<70%rF)
Operating height ..................................max. 2000 m
Storage conditions ...............................-20 °C to +60 °C (<80%rF)
Weight .................................................approx. 210 g
Dimensions (LxWxH) ............................138 x 68 x 37 (mm)
Measuring category ..............................CAT III 600 V
Degree of contamination ......................2
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The accuracy is
valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than 75%, non-condensing.
Direct voltage (V DC)
Range
200.0 mV
2000 mV
20.00 V
200.0 V
600 V
Overload protection 600 V; Impedance: >1 MΩ
42
Accuracy
±(0.7% + 3)
±(1.0% + 3)
Resolution
0.1 mV
1 mV
0.01 V
0.1 V
1 V