6. Mounting
All inclination transmitter can be mounted either directly
with 3 clamping brackets to the item being measured or with
a mounting plate with 4 cheese head screws M6. Please take
care that the installation position of the inclination transmitter
is perpendicular to the gravity of the earth. The inclination
transmitter are supplied standard with mounting plate but
without cheese head screws M6.
Mounting versions

7. Electric connections

To connect the electrical lines, the inclination transmitter has
a sensor connector M12x1 / 4 poles.
Wiring connection
N
S
X axis
14
sin
D
cos
A
μC
A
B
E
-
+
+
0 V 24 V
4-20 mA
• Avoid impacts or shocks on the housing.
• Do not deform housing.
• Do not open or mechanically modify the
device.
Drilling aund cut­out diagrams (for mounting transmitters)
Ø66.2
Ø66.2
[2.606]
[2.606]
60.1
60.1
[2.366]
[2.366]
M6
PIN configuration
Pin assignments:
1 = 0 V
2 = + 24 V DC
4 = 4 ... 20 mA
• Do not electricly modify the device nor
carry out any wiring work when energised.
• Do not plug in or unplug electric connection
when energised.
M6
4
3
2
1