Exit Programming Mode; How To Program The Paging Function; How To Program The Self Ignition Function - Comelit HFX-7000M Manuel Technique

Masquer les pouces Voir aussi pour HFX-7000M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3
Select the key to be associated with the function
„ Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4

Exit programming mode

„ To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the privacy LED switches off
5
When programming is complete,
„ Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch setting,
the keys control the programmed functions; the NON-programmed keys control functions
referred to on line 0000 (see the table above).
„ Restore the user code setting on S1, see

4.2.3.3 HOW TO PROGRAM THE PAGING FUNCTION

Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
„ Set S2 DIP switch 5-6 to the combination 01
» the privacy LED flashes
2
1. Choose the function: refer to the the following table and select a S2 DIP switches combination
in which the paging function (PAG) is listed for the keys you wish to program.
DIP S2
DIP 1
DIP 2
DIP 3
0
0
0
1
0
0
0
1
0
1
1
0
0
0
1
1
0
1
0
1
1
0
0
1
1
0
1
0
1
1
1
1
1
2. Addressing:
„ for internal paging set S1 DIP switches with the same user code of the internal unit.
„ for general paging to another user code set S1 DIP switches with the desired address in
accordance with
"TAB. A User code" on page 30.
3
Select the key to be associated with the function
„ Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
„ To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the privacy LED switches off
5
When programming is complete,
„ Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch setting,
the keys control the programmed functions; the NON-programmed keys control functions
referred to on line 0000 (see the table above).
„ Restore the user code setting on S1, see

4.2.3.4 HOW TO PROGRAM THE SELF IGNITION FUNCTION

Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
„ Set S2 DIP switch 5-6 to the combination 01
» the privacy LED flashes
"TAB. A User code" on page 30.
KEY PROGRAMMING
DIP 4
0
0
0
0
PAG /
0
0
0
1
1
1
1
PROG
"TAB. A User code" on page 30.
P1
P2
PAG
PAG
Example
For
= general paging to
user code 3
25