7. Troubleshooting

A system fault will be indicated by an acoustic signal and one of the following fault codes
on the remote control display:
Display
Fault
E03 E
Overheated coil
E05 E
Temperature increase of less
than 1°C (1.8°F) every 15
seconds (or every 30 seconds)
E06 E
Temperature probe not
connected (or defective) or
excessive temperature drop
E10 E
Electronics communication
problem
E11 E
Electronics communication
problem
E12E
Electronics communication
problem

8. Spare parts

TIH 220-PMV
TIH 220-PLV
TIH 220-Y10
TIH 220-Y6
TIH 220-YS
TIH CP
TIH RC
TIH CB25A
TIH CB50A
TIH P20
SKF TIH 220m
Power print 400 - 460V, 50 - 60 Hz
Power print 200 - 240V, 50 - 60 Hz
Yoke 70 x 70 x 430 mm
Yoke 40 x 40 x 430 mm
Support yoke set - 70 x 70 x 150 mm (2x)
Control print
Remote control
Circuit breaker 25A for TIH 220m/MV
Circuit breaker 50A for TIH 220m/LV
Temperature probe K type incl. cable and plug
Action
Wait until the induction coil cools.
Switch the heater OFF and then
back ON
Check the temperature probe
connection. If the connection is OK,
select the 30 second interval as
described in section 6 or operate
the heater in TIME MODE
Check the temperature probe
Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair
Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair
Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair