Changing the battery pack
Removing the battery pack
Press and hold the two buttons [2-1].
Slide the battery pack forwards to re-
move.
remove
insert
2
Inserting the battery pack
Slide the battery pack onto the retainer
on the underside of the handle shown in
Fig. until it engages..
Charging the battery pack
The battery pack is delivered partially
charged. Charge the battery pack com-
pletely before using for the first time.
10
klick
Operation
[2]
To charge the battery pack, slide all the
way onto the retainer
er.
To remove, slide off the charged battery
pack in similar fashion.
3-1
The charger TRC 3 can be used to charge all
Festool battery packs of the BPS and BPC se-
ries. The charger automatically detects the
type of the inserted battery (NiCd, NiMH or
2-1
LiIon). A microprocessor controls the charg-
ing process in line with the charging state,
temperature and voltage of the battery pack.
The LED
respective operating status of the charger.
LED yellow - lit continuously
Charger is ready to use.
LED green - flashing quickly
Battery pack is charged to maximum capac-
ity.
LED green - flashing slowly
Battery pack is charged with reduced cur-
rent, LiIon is charged to 80 %.
LED green - lit continuously
Battery pack is fully charged, or charging is
not started again, because the battery is
charged to more than 80 %.
LED red - flashing
Battery temperature is outside the permitted
range.
LED red - lit continuously
General fault display, e.g. incomplete con-
[3]
tact, short circuit, battery pack faulty, etc.
Charger wall mounting TRC 3
There are two elongated holes on the back of
the TRC 3 for mounting the charger to a wall
[3-1]
[3-2]
on the charger indicates the
on the charg-
3-2