mount ed in a different way: Unscrew the
clip, turn it (clockwise or counter-clockwise
by 90° or by 180°), then retighten it .
9) To switch off the transmitter after operation,
set the power switch (2) to OFF . The display
shortly indicates
completely .
5.1 Adjusting the
transmission frequency
1) Keep the key SET (7) pressed for 2 s . The
display shortly indicates
turns to its previous indication . MHZ flashes
on the display .
Note: To exit the adjusting mode without mak-
ing an adjustment, press the key SET repeatedly
until the display shows
turns to normal operation .
2) Adjust the frequency with the cursor keys:
each time the key
creases by 125 kHz; each time the key
is pressed, it increases by 125 kHz .
Note: When using several wireless sys tems at the
same time, the radio frequencies of the individ-
ual systems should be carefully matched to each
other to prevent interference .
3) Press the key SET to save the adjustment .
The display shortly indicates
justing mode is exited, the unit returns to
normal operation .
5.2 Locking / unlocking the unit
With the unit locked, it is not possible
a) to switch off the unit; if the power switch (2)
is set to OFF with the unit locked, the display
shows
.
b) to change the transmission frequency .
5.2.1 Activating the lock function
1) First call up the frequency adjusting mode:
Keep the key SET (7) pressed for 2 s .
2) As soon as the indication MHZ flashes on
the display, shortly press the key SET to go
to the lock mode:
display (locking deactivated) .
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
and then extinguishes
and then re-
. Then the unit re-
(6) is pressed, it de-
, the ad-
flashes on the
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
®
3) Press the key
display .
4) Save the adjustment by pressing the key SET .
is shortly displayed, the adjusting
mode is exited, the unit returns to normal
operation .
5.2.2 Deactivating the lock function
1) The power switch (2) must be set to ON .
2) Keep the key SET (7) pressed for 3 s until
flashes on the display .
3) Press the key
display .
4) Save the adjustment by pressing the key SET .
is shortly displayed, the adjusting
mode is exited, the unit returns to normal
operation .
6 Specifications
(5)
Type of unit: . . . . . . . . . . PLL multifrequency
Radio frequency range: . 518 – 542 MHz
Audio frequency range: . 40 – 18 000 Hz
Frequency stability: . . . . ±0 .005 %
Transmitting power: . . . . 10 mW (EIRP)
Ambient temperature: . . 0 – 40 °C
Power supply: . . . . . . . . two 1 .5 V batteries
Dimensions (W × H × D): 78 × 190 × 34 mm
Weight: . . . . . . . . . . . . . 160 g
Connection: . . . . . . . . . . mini XLR
1 = ground
1
3
2 = signal input
2
3 = operating voltage of 5 V for
Subject to technical modification .
(5):
flashes on the
(6):
flashes on the
pocket transmitter
of size AA (R6)
the microphone
9