ELEMENTS SUSPENDUS D'UNE PROFONDEUR DE 45,0 CM - MONTAGE MURAL – CARACTERISTIQUES INDISPENSABLES POUR LA COMPOSITION DU MUR
MONTAGE · ASSEMBLY · MONTAGE · MONTAGE
Attention! The nature of the wall must be checked carefully by qualified personnel before assembly. Assembly may then only be carried out by qualified persons
carefully observe these assembly instructions. The plastic TOX PSD-SL 8 x 90 mm wall plugs is in accessories bag 1927 are only suitable if the characteristics of the wall
and the pressure resistance levels are as stated in the table below. The unit must not be assembled on light walls or masonry. In all other cases it is essential that a different
and appropriate type of mounting is chosen by a qualified person. hülsta cannot be held responsible for the correct choice of a different method of mounting. During
assembly please also make sure that there are no electrical installations or other utility lines near the mounting area. This must be checked using an appropriate search
device. Please note that plastic pipes will not be detected.
The set of wall fittings contained in accessories bag 1927 is only suitable for use in connection with the types of walls stated below. Please note that the pressure
resistance levels must under no circumstances fall below those stated.
Concrete
Concrete and
Solid brick
solid brickwork
Solid sand-lime brick
Vertical coring
brick
Perforated brick
with a dense
Concrete precision
structure
block
(Pressure
resistance
> 10.0 N/mm²)
Perforated sand-
lime brick
Solid brick
with a porous
Porous concrete
structure
Anchoring depth
Screw length
Depth of drilled hole
SEITE 50
MONTAGEANLEITUNG
HÄNGEELEMENT 45ER TIEFE
WANDBEFESTIGUNG -NOTWENDIGE WANDBESCHAFFENHEIT
WALL UNITS 45.0 CM DEEP - WALL MOUNTING - REQUIRED STRUCTURE OF WALL
HANGELEMENTEN 45,0 CM DIEP - WANDBEVESTIGING - VEREISTE WANDSTRUCTUUR
Accessories bag 1927
4x
DIN 571 / 6x100 8.8
PSD-SL Ø 8x90
Pressure resistance
DIN 1045/1
>/= C20/25
>/= 20 N/mm²
ETAG 001
Pressure resistance
DIN 105
Mz 12
>/= 12 N/mm²
DIN EN 771-1
Pressure resistance
KS 12
DIN 106
>/= 12 N/mm²
KSL 12
DIN EN 771-2
Pressure resistance >
HIz 12
10 N/mm²
DIN 105-1
Pressure resistance >
Z-17.1-636
PNE
10 N/mm²
Pressure resistance >
ST 9
10 N/mm²
DIN 105-1
Pressure resistance
>/= 2,5 N/mm²
4x
4x
DIN 125 / 6.4
Recommended kind of drilling:
Hammer (Impact) drilling: Drilling with a hammer drill (high setting, better
drilling progress) for holes which need to be of a high quality. Suitable for
solid walls with a dense structure (concrete, etc). Holes must always be
thoroughly cleared of any drilling remains afterwards.
Percussion drilling: Drilling with a percussion drill (low setting) for brick-
work of a dense structure (solid bricks, solid sand-lime bricks). Holes
must always be thoroughly cleared of any drilling remains afterwards.
Rotary drilling: With a normal power drill, without percussion setting
in perforated bricks (so that the connecting sections do not break and
the hollow section become too large). Holes must always be thoroughly
cleared of any drilling remains afterwards.
Rotary drilling: With a normal power drill, without percussion setting in
porous concrete. Holes must always be thoroughly cleared of any drilling
remains afterwards.
Depth of drilled hole
The hole itself must be deeper than the depth of anchoring. The extra space
is required to take the screw, which must always protrude beyond the tip
of the wall plug, especially in the case of plastic plugs.