Burkert PTB 00 ATEX 2129 X Instructions De Service page 8

Appareils avec mode de protection ii 2g/d eex m et ii 2g eex em
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Minimum dimensions of the valve bodies:
32 mm x 32 mm x 10 mm (L x W x H)
A larger valve body with better heat conductance may be attached at any
time.
3. Individual installation
The solenoid coil types AC10-..-.- PD47 to AC10- ..-.-PD72 , are only suitable
for individual installation.
4. Operating temperature range
Comply with the operating temperature listed for each type in the "Electrical
Data"!
5. Ambient temperature > 55 °C
For solenoid coil types AC10-..-6-PD53 and AC10-..-6-PD66, a heat-resistant
cable tail is used for ambient temperatures > 55 °C!
Use in Petrol tanks
The solenoid coil types AC 10-..-.-... may also be used for the control of petrol
in category 2 when no air and no oxygen are present in the closed system.
This also applies during start-up and shut-down of the system.
ATTENTION!
The coil is mounted on the armature guide
tube.
It may be disassembled only by the
manufacturer!
The valve always represent a closed
system.
Temperature conditions on the solenoid coil
type AC10 at 60 °C ambient temperature.
6 - 00 ATEX 2129 X
When using the devices in petrol pumps for the control of
petrol in category 2, a valve body made of metal (brass,
aluminium or stainless steel) must be employed!