Installation
The following instructions about
installation and maintenance must
be carried out by qualified personnel
in compliance with the regulation in
force. The regulation to be applied
for this type of installation is NBN D
5I.003 : "Installations functioning
with combustible gas lighter than
air".
The side walls of the unit in which
the hob is going to be installed, must
not exceed the height of the working
top.
Avoid installing the appliance in the
proximity of inflammable materials
(e.g. curtains, tea towels etc.).
The appliance must be electrically
disconnected
interventions. If any electric supply
to the appliance is required to carry
out the work, ensure all the
necessary precautions are followed.
Gas Connection
It is indispensible that the connection to the
gas mains are carried out by means of an
AGB tap. Choose fixed connections or use a
flexible pipe in AGB (stainless steel).
If using flexible metallic pipes, be careful they
do not come in contact with mobile parts or
they are not squeezed. Use the same
attention when the hob is combinated with
an oven.
This hob can be operated by Slochteren gas
(G25) with a nominal pressure of 25 mbar or
by natural gas with nominal pressure of 20
mbar. No regulation is required for use by
these two types of gas. Before fitting the
appliance ensure that the installation has the
correct voltage for the appliance. At full
capacity, the drop in pressure must not
exceed 5%. Such a drop in pressure is
caused by the following parameters:
-
maximum capacity of meter;
-
diameter and lenght of the tube in
front and behind the meter;
before
all
-
section of transit of variuos tubes
positioned on the circuit;
-
diameter of eventual connections.
To ensure a correct operation, a saving of
energy and the long-life of the appliance, the
voltage pressure of the appliance must
correspond to the recommended values.
The adjustable connection is fixed to the
comprehensive ramp by means of a
threaded nut G 1/2". All the components
shown in the figure have already been
assembled in the factory.
The appliance, before leaving the factory, has
been tested in order to give you the best
results.
Important
When the final connection has been made, it
is essential that a thorough leak test is carried
out on the hob and installation. Use some
soapy water, never a flame.
A - Ramp with ending nut
B - Seal
C - Adjustable connection
11
progress