Conformity
Standards
Approvals
Vibration resistance
Climatic conditions
Degree of pollution
Permissible
Permissible
t
temperature ranges
t
Permissible installation
height
Mounting positions
Free space
Free space
EMC8.
Noise emission
Discharge current to PE (to
EN 50178)
Type of
protection9.
Protection measure against
Insulation of control circuits Safe mains disconnection:
Insulation strength
L
CE
Low-Voltage Directive (73/23/EEC)
EMC Directive (93/68/EEC)
DIN EN 60947-4-2
Semiconductor motor control devices and starters for AC
voltage
UL 508
Underwriter Laboratories (File-No. E132659)
Power Conversion Equipment
(in preparation)
Acceleration resistant up to 4g (Germanischer Lloyd, general conditions)
Class 3K3 to EN 50178 (without condensation, average relative humidity 85
%)
VDE 0110 part 2, pollution degree 2
Transport
-25 °C ... +70 °C
Storage
-25 °C ... +60 °C
Operation
Motor mounting: -25 °C ... +60 °C
Wall mounting: -25 °C ... +40 °C
0 ... 4000 m amsl
reduce the rated output current by 5%/1000 m above 1000 m amsl
Every mounting position is permissible
above
100 mm
to the sides
100 mm
Compliance with EN 61800-3/A11
Compliance with limit value class B to EN 60947-4-2
< 3.5 mA
IP 55; NEMA 1: Protection against contact
IP 65; NEMA 4 (with protection cover over AIF interface)
Motor overtemperature (input for PTC or thermistor, I
Double/reinforced insulation to EN 50178
Overvoltage category III to VDE0110
EDK71MMXXX-020 DE/EN/FR 1.0