IEC 60068-2-6
IEC 60068-2-29
Electrical data
Nominal output voltage
output
Output voltage range
Output current
Battery return current

Mechanical data

Cooling
Dimensions l x w x h
Weight (without cable)
Environmental
Operating temperature
conditions
Storage temperature
Climate class
Degree of protection
Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; accelera-
tion 5 g)
Repetitive shock (25 g / 6 ms / 1000 shocks)
12 V DC
2 V - 14.4 V
30 A at 13.5 V DC
Convection
270 x 168 x 100 mm
10.6 x 6.6 x 3.9 in.
-20 °C - +40 °C (>30 °C derating)
-4 °F - +104 °F (>86 °F derating)
-40 °C - +85 °C
-40 °F - +104 °F
< 1 mA
2.2 kg
4.9 lb
B
IP40
51