Technical data

Electrical data in-
Mains voltage
put 230 V
Mains frequency
Mains current
Mains fuse
Efficiency
Effective power
No-load power consumption
Protection class (with ground conductor)
Maximum permitted mains impedance at the interface
(PCC) to the public grid
Mark of conformity
EMC device class

Standards 230V

IEC 60068-2-6
IEC 60068-2-29
EN 60335-1
EN 61000-3-2
EN 61000-6-2
EN 61000-6-4
Electrical data in-
Mains voltage
put 120 V
Mains frequency
Mains current
Mains fuse
Efficiency
Effective power
No-load power consumption
Protection class (with ground conductor)
Maximum permitted mains impedance at the interface
(PCC) to the public grid
Mark of conformity
EMC device class

Standards 120V

UL1236
C22.2 No 107.1-01
FCC CFR 47 Part 15
50
Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; acceleration 5 g)
Repetitive shock (25 g / 6 ms / 1000 shocks)
EN 60335-2-29
(EN 61000-4-2, EN 61000-4-3, EN 61000-4-4)
(EN 61000-4-5, EN 61000-4-6, EN 61000-4-11)
(Class A)
(Class A)
~ 230 V AC ±15%
50/60 Hz
max. 2.9 A eff.
max. 16 A
max. 95%
max. 420 W
max. 1.7 W
I
none
CE
A
~ 120 V AC ±15%
50/60 Hz
max. 7.3 A eff.
max. 20 A
max. 93%
max. 420 W
max. 6.9 W
I
none
cTÜVus
A