Expert Settings; Access; Ambient Temperature Sensor Adjustement - vogelundnoot BLOWER 950W Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EXPERT SETTINGS

ACCESS

You access to expert settings in 5 steps.
From Auto, Comfort, Eco or Frost protection mode :
Information display
1
Press for 5
seconds
Information display
Setting sequence:

Ambient temperature sensor adjustement

factory settings
AMBIENT TEMPERATURE SENSOR ADJUSTEMENT
In which case if the temperature measured (measured by reliable ther-
mometer) is diff erent by at least 1°C or 2°C compared to the setting
temperature of the radiator.
The calibration adjusts the temperature measured by the ambient tem-
perature sensor to compensate for a deviation from + 5°C to - 5°C by
intervals of 0.1°C.
1- If the room temperature diff erence is negative, example :
To correct, then proceed as follows :
Sensor temperature = 24°C
Press brie y
twice
Long and simultaneous
10 seconds press
Setting the energy type
Information displays
1
Pro
= Expert settings
Setting the power
Decrease the temperature measured by the ambient temperature sen-
sor by 2°C by pressing
In our example the measured temperature by the sensor goes
from 24°C to 22°C.
2- If the room temperature diff erence is positive, example :
To correct, then proceed as follows :
Sensor temperature= 21°C.
Press brie y
Internal temperature monitoring
.