INSTALLER SETTINGS
ACCESS
You access to User settings in 4 steps:
From Auto, Comfort, Eco or Frost protection mode :
Information display
1
Press for 5
seconds
Setting sequence:
Con guration of detection modes
CONFIGURATION OF DETECTION MODES
1
On
OFF
2
M16MI328 A02_01/18
Information displays
Press brie y
twice
Dual optimization feature
1
Press for 10
seconds
Super Comfort
PIN code lock
2
ON
OFF
DUAL OPTIMIZATION FEATURE
This feature is available on the device equipped with a occupancy de-
tector.
Depending on various parameters: room inertia,
ambient temperature, desired temperature, the device calculates and
optimizes the programming for each heating period whether set to
Comfort or Savings (Eco):
will calculate the best compromise in order to guarantee maximum
energy savings throughout the programmed increase and decrease
phases.
In this mode, a slight drop in the temperature level at the beginning
and end of the comfort period is allowed to maximize energy savings.
calculates the best compromise in order to guarantee maximum
comfort during the programmed increase and decrease phases.
In OPTI COMFORT mode, the priority is given to anticipating and
maintaining the comfort temperature during periods of detected oc-
cupancy.
InSt
= Installer
settings
Press brie y
Restoring factory settings
the devices inbuilt algorythmes
the device intelligence
16