Technical Data

Power supply:
Protection category: For dry rooms only
Automatic cutout:
End-of-travel
cutoff / Force limit:
Push and pull force:
Motor:
Transformer:
Connection:
Special functions:
01.2004 V1.0 / 401 RE
230/240 V, 50/60 Hz
Standby approx. 1 W
Is automatically programmed
separately for both operational
directions.
Self-learning, non-wearing,
since no mechanical switches
are used, additionally integrated
excess travel stop of approx.
140 s. Automatic cutout read-
justs itself during each door
cycle.
see type plate
DC motor with Hall sensor
with thermal overload
protection
Connection technique without
screws for external equipment
with safe low voltage of 24 V DC,
e.g. internal and external but-
tons for impulse control.
- Operator lighting
- STOP/cutout switch can be
connected
- Photocell and closing edge
safety device can be con-
nected
- Warning light 230 V AC can
be connected
- Options relay for connecting
an external light
Quick release:
Remote control:
Universal fitting:
Door speed:
Airborne noise
emission Garage
door operator:
Boom:
6

Dismantling and Disposal

Please note that should dismantling become necessary,
the safety regulations apply here also and must be
observed accordingly. Disposal must be carried out in
accordance with the respectively applicable regulations
concerning the disposal of scrap.
Subject to technical changes!
Issue: September 2003
In the event of a power failure,
actuated from the inside via a
pull cord
4-button hand transmitter RC
BE 868/4 (868.360 MHz) and
separate receiver.
for up-and-over and sectional
doors
approx. 135 mm/s (depending
on size and weight of door)
≤ 70 dB (A)
Extremely flat (no more than
30 mm high) with integral door
security kit. Boom in toothed
belt or chain version.