CV62
Back-EMF: max. adjustment
Limits the total adjustment in motor voltage to a maxi-mum
deviation from setpoint. If there is a very large load on the
motor, the adjustment will not exceed this value - for more
realistic operations, so that locos will slow a bit on grades.
0 = no adjustment, 255 = maximum adjustment
CV67
Speed steps table, user-programmable (see CV 29): The
to
speed table is always saved with 28 speed steps to be
CV94
programmed in CV67 to CV94.
With LGB MTS, every second value is skipped (14 speed
steps).
Factory-set speed steps:
7, 9, 11, 13, 16, 20, 24, 28, 32, 36, 42, 48, 54, 60, 68, 76,
84, 92, 102, 112, 124, 136, 152, 168, 188, 208, 230, 255
Pre-set values for user-programmable speed steps:
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96, 104, 112,
120, 128, 136, 144, 152, 160, 168, 176, 184, 192, 208,
224, 240, 255
Note:
The speed steps are factory-set and needn't be changed.
We recommend the 55045 MTS PC Decoder Programming
Module for programming.
Example for bit programming:
CV 29: A loco shall run in reverse direction with user-
programmed speed steps, analog operation shall
be possible:
Bit 1 = 1, Bit 2 = 0, Bit 3 = 4, Bit 4 = 0, Bit 5 = 16,
Bit 6 = 0. 1+4+16=21.
Thus, program CV 29 to function value 21.
(0-255)
[255]
(0-255)
23