Installation; Connection - Cristec JBNUM II-CPS3 Manuel D'utilisation

Le moniteur de batterie
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

► Battery Monitor connection
Disconnect the charger from AC power-supply and also from the batteries (no input
1
voltage and no output voltage) and the others energy sources.
Place first the 10m cable with its RJ11 connector between the battery and the LCD
2
monitor final location. Make sure that it will not be too much twisted or bended and that
it will not be located near an electrical cable with interference.
Installation on a battery:
3
Battery side: connect the shunt side « + » of the battery, beware of the polarity,
« B+ » battery side, « U+ » utilization/power sources side. Connect the green
PHOENIX connector on the battery with the 2 wires, « + » on the terminal « + » of
the battery, « - » on the terminal « - » of the battery. Connect the RJ11 cable on the
measuring board.
Installation on an energy source:
Energy source side: connect the shunt side « + » of the energy source, beware of
the polarity, « U+ » power sources side, « B+ » utilizations / batteries side. Connect
the green PHOENIX connector on the energy source with the 2 wires, « + » on the
terminal « + » of the energy source, « - » on the terminal « - » of the energy source.
Connect the RJ11 cable on the measuring board.
When used with more than one battery bank / energy source, all « - » must
be connected together (see wiring diagram page 39, 40, 41, 56 and 57). In case of
non compliance with the wiring, risk of damage to the equipment.
Display Side: connect the RJ11 cable on one of connectors 1, 2 or 3, depending on
4
the number of monitored batteries / energy sources.
If additional voltages measurements (4 and 5 connectors):
Installation on a battery: connect the red cable length 10m on the terminal « + » of
3
the voltage to be measured.
Display side: connect the red cable length 10m on the connectors 4 or 5
4
(See wiring page 39, 40, 41, 56 and 57)