FAULTS TREE:
Below we give a description of some malfunctions that, on the basis of internal statistics, occur most frequently
and caused by wear,
exposure to particularly diffi cult climatic conditions or failures.
Therefore, based on the data in our possession, these are the most common cases and relative method for seeking
the fault according
to the following:
1. The brush does not start:
o No voltage supply to brush.
• Make sure that the voltage supply is arriving.
• Check that differential and/magnetothermal switches are in the correct position.
• Check the integrity and correct connection of the supply cable and the motor cable.
o Supply voltage too low: the display shows alarm message "2".
• For brush with 230VAC supply, check that voltage is more than 180VAC.
• For brush with 115VAC supply, check that voltage is more than 85VAC.
o Supply voltage too high: the display shows alarm message "1".
• For brush with 230VAC supply, check that voltage is less than 270VAC.
• For brush with 115VAC supply, check that voltage is less than 140VAC.
o Fuse F1 burnt out.
• Remove voltage from brush and replace the 10A fuse F1, pressing the cap and turning slightly anti-clockwise.
• Supply voltage to brush and check that the red LED DL1 lights up. If the fuse burns immediately, the board is
faulty.
o Red LED DL1 off.
• Check integrity of fuse and that it is inserted correctly in its housing.
• Carry out checks as above.
o The start motor limit switch does not work.
• Make sure that when moving the brush the limit switch is released and pressed correctly.
• Check that the limit switch is positioned correctly.
• Check that the limit switch is connected correctly to terminals 9M and 10G as shown.
• Replace the limit switch.
o Faulty board.
Replace board.
2a. The brush continues to function (RotaBrush Classic, RotaBrush Twin):
o Dip-switch SW1 not confi gured correctly.
• Confi gure the dip-switch SW1 (1 and 2 OFF).
o The start motor limit switch does not work.
• Make sure that when moving the brush the limit switch is released and pressed correctly.
• Check that the limit switch is positioned correctly.
• Check that the limit switch is connected correctly to terminals 9M and 10G as shown.
• Replace the limit switch.
2 b. The brush continues to function (Cow Cleaner Swing):
o Dip-switch SW1 not confi gured correctly.
• Confi gure the dip-switch SW1 (1 and 2 OFF).
30