GRAPHIC SWITCHER II™
10-5.VALUES DESCRIPTION TABLE (continued)
ASCII
RESPONSE
COMMAND
E
EFF
ed
EFD
el
SEQS
ei
SEQV
er
SEQC
ut
tkev
ja
TALA
jb
TALB
jc
TALC
jd
TALD
IL
ILD
il
ild
ID
IFD
COMMAND
DESCRIPTION
Effect selection.
Effect duration selection (from
0.5s to 25.5 seconds by 0.1s
step).
Selection of a function of the
sequence mode.
Validation of the selected
function.
Current step selection.
Status of the pre-selected input
(read only).
Input number for TALLY1
Input number for TALLY2
Input number for TALLY3
Input number for TALLY4
This command allows to
calculate the input line
frequency in Hz (MAIN).
This command allows to
calculate the input frame
frequency in Hz (PREV).
This command allows to
calculate the input frame
frequency in Hz (MAIN).
Chapter 10 : RS-232 PROGRAMMER'S GUIDE (continued)
VALUE DESCRIPTION
00 = CUT.
01 = FADING: automatic from 0.5 to 25 seconds or T-BAR.
02 = TITLE: automatic from 0.5 to 25 seconds or T-BAR.
03 = TITLE: holding.
04 = SHADOW TITLE: automatic from 0.5 to 25 seconds or T-BAR.
05 = SHADOW TITLE: holding.
06 = HOR WIPE, Left to Right: automatic from 0.5 to 25 sec or T-BAR.
07 = HOR WIPE, Right to Left: automatic from 0.5 to 25 sec or T-BAR.
08 = HOR WIPE, to Center: automatic from 0.5 to 25 seconds or T-BAR.
09 = HOR WIPE, from Center: automatic from 0.5 to 25 sec or T-BAR.
10 = VERT WIPE, Up: automatic from 0.5 to 25 seconds or T-BAR.
11 = VERT WIPE, Down: automatic from 0.5 to 25 seconds or T-BAR.
12 = VERT WIPE, to Center: automatic from 0.5 to 25 seconds or T-
BAR.
13 = VERT WIPE, from Center: automatic from 0.5 to 25 sec or T-BAR.
14 = DIAMOND WIPE, to Center: automatic from 0.5 to 25 sec or T-
BAR.
15 = DIAMOND WIPE, from Center: automatic from 0.5 to 25 sec or T-
BAR.
16 = Normal PIP : automatic from 0.5 to 25 seconds or T-BAR.
17 = Normal PIP : holding.
18 = Fade PIP : automatic from 0.5 to 25 seconds or T-BAR.
19 = Fade PIP : holding.
20 = POP.
5 = 0.5 second
...
255 = 25.5 seconds.
0 = no function selected.
1 = add step function.
2 = play sequence function.
3 = list sequence function.
4 = erase last function.
5 = clear sequence function.
1 = validate the selected function of the sequence mode (automatic reset).
For example: • If add step selected, this command add a step into your
sequence.
• If erase last selected, this command erases the last step
of your sequence.
1 = select step # 1.
......
40 = select step # 40.
The command indicates if the pre-selected input is ready to commute or
not.
0 = pre-selected input not ready to commute. The validation of the
selected function can not be activate.
1 = pre-selected input ready to commute. The validation of the selected
function can be activate.
Identical as C command.
Identical as C command.
Identical as C command.
Identical as C command.
Line frequency (in kHz) = (UNIT VALUE) ÷ (ILD VALUE).
Line frequency (in kHz) = (UNIT VALUE) ÷ (ild VALUE).
Frame frequency (in Hz) = (Line frequency in Hz) ÷ (IFD VALUE).
PAGE 39