Chapter 7 : LCD FUNCTIONS DESCRIPTION (continued)
4-6[sequence mode] + ENTER.
This mode allows programming a sequence of transition. The sequence can also be activated at any time during the
show, and controlled step by step (one step = pre-selection + transition) by one key only: the STEP key. This function
allows to simplify the use of the device during a show.
4-6-1 [list sequence] + ENTER.
This function allows to verify the programmed sequence. Turn the
4-6-2 [play sequence] + ENTER.
This function allows to start or stop the programmed sequence.
IMPORTANT: Before starting, verify that the correct input is displayed onto the MAIN output.
Select start with
the first pre-selected source is displayed onto the PREVIEW output. Press the STEP key to execute the first
transition and pre-select the next source and so on.
NOTE: For holding effect (i.e. : holding PIP): the first push on STEP allows to activate the effect and a
To stop the sequence press ENTER, the LCD menu displays [play sequence]: select stop with
validate with ENTER. The STEP key turns OFF.
4-6-3 [add step] + ENTER.
This function allows to add a step into your sequence. A step is composed of an input pre-selection and a
transition. Each new step is added at the end of your sequence.
Proceed as follow:
Select start and validate with ENTER. The STEP key turns ON.
Pre-select an input with the input selection keys (the key is blinking and the image appears onto the
PREVIEW output).
Select a transition: Press one of the four effect keys (1, 2, 3, 4) and select the needed effect.
Press on STEP to add this new STEP into your sequence. The transition is displayed onto the MAIN output.
NOTE: For holding effect (i.e. : holding PIP): the first push on STEP allows to activate the effect and a
Repeat the operations
NOTE: You can add up to 40 STEPS into your sequence.
Select stop to deactivate the add step function. The STEP key turns OFF.
4-6-4 [erase last] + ENTER.
Erases the last step of the sequence.
4-6-5 [clear sequence] + ENTER.
Erases all of the sequence.
PAGE 26
and press ENTER to start the programmed sequence. The STEP key is blinking and
second push on STEP stops the effect.
second push on STEP to stops the effect.
,
,
to add any new steps.
GRAPHIC SWITCHER II™
knob to display the list.
and