Imer Group HPSTAR 150-13 Manuel D'utilisation page 51

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTE
If the high pressure washer still cannot start, please contact the IMER FRANCE dealer or the
nearest After-Sales Service to get information and to be instructed with measures to take.
THE PUMP IS MEETING THE FOLLOWING PROBLEMS:
No pressure rise;
Intermittent pressure;
Pressure jolt;
Low water flow;
1) The pump sucks up air.
2) Input water is blocked.
3) Unsuitable water supply.
4) The input hose is pinched.
5) Leak on the input hose.
6) The strainer of the input hose (b) (Fig. B) of
the high pressure washer is blocked.
7) Water temperature is over 30°C.
8) The high pressure hose leaks or is blocked.
9) The gun leaks.
10) The nozzle is blocked.
THE DETERGENT CANNOT MIX WITH THE WATER JET:
1) Siphoning pipe not immersed into the
detergent.
2) The PVC pipe strainer device is blocked.
3) Nozzle in high pressure mode.
NOTE
If the high pressure washer still cannot start, please contact the IMER FRANCE dealer or the
nearest After-Sales Service to get information and to be instructed with measures to take.
1) Control the delivery pipe. Make sure it is not
porous.
2) Clean the input.
3) Provide a suitable water flow rate. Select
a water feeding pipe with a convenient
diameter (see section 5.1. Connection to the
water supply).
4) Eliminate the pinching.
5) Repair the leak.
6) Inspect and clean the strainer of the input
hose of the high pressure washer (b) (B)
7) Provide a colder water supply.
8) Unclog the high pressure hose or replace it.
9) Replace the gun or the O-rings.
10) Clean the nozzle.
1) Immerse the PVC pipe strainer device into
the detergent.
2) Clean or replace the PVC pipe strainer device .
3) Select the low pressure mode.