FUST NOVAMATIC KS-TF 309-IB Notice D'utilisation page 42

Masquer les pouces Voir aussi pour NOVAMATIC KS-TF 309-IB:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

What to do if...
Problem
The appliance is noisy.
The lamp does not work.
The compressor operates
continually.
Water flows inside the re‐
frigerator.
Water flows on the floor.
The temperature in the ap‐
pliance is too low/too high.
Side panels of the appli‐
ance are warm.
Possible cause
The appliance is not sup‐
ported properly.
The lamp is in stand-by
mode.
The lamp is defective.
Temperature is set incor‐
rectly.
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The water outlet is clogged.
Food products prevent wa‐
ter from flowing into the
water collector.
The melting water outlet is
not connected to the evap‐
orative tray above the com‐
pressor.
The temperature regulator
is not set correctly.
The food products temper‐
ature is too high.
Many food products were
stored at the same time.
This is a normal state
caused by operation of the
heat exchanger.
Solution
Check if the appliance stands
stable.
Close and open the door.
Refer to "Replacing the lamp".
Refer to "Operation"/"Control
panel" chapter.
Wait a few hours and then
check the temperature again.
Refer to climate class chart on
the rating plate.
Allow food products to cool to
room temperature before stor‐
ing.
Clean the water outlet.
Make sure that food products
do not touch the rear plate.
Attach the melting water outlet
to the evaporative tray.
Set a higher/lower tempera‐
ture.
Let the food products temper‐
ature decrease to room tem‐
perature before storage.
Store less food products at the
same time.
Make sure that there is at
least 30 mm of space between
each side of the appliance and
the surrounding furniture when
the ambient temperature ex‐
ceeds 38°C.
42

Publicité

Chapitres

Table des Matières
loading

Table des Matières