Installation
Location Requirements
Select a location with a solid floor. Dryers installed
in
residential
garages must be elevated
18 inches (46 cm)
above the floor.
No other fuel burning appliance
should be installed
in
the same closet with the dryer.
The dryer must not be installed
or stored in an area
where it will be exposed to water and/or weather.
Leveling
legs can be adjusted
from inside the dryer
with a 1/4 inch driver. All four legs must rest firmly on
the floor so the weight of the dryer is evenly
distributed.
The dryer must not rock.
The dryer needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown in Figure
19.)
!iii!iii!ill
I
_ J
i; i
FRONT VIEW
(w/o Closet Door)
i
F
q
E
2 (G)
- .-.
SIDE VIEW
3
FRONT VIEW
(Closet Door)
F
DRY1991N
Free Standing/Alcove
Closet Installation
Area
Description
Installation
A
Dryer sides and rear clearance
0 in. (0 cm)
0 in. (0 cm)
B
Dryer top clearance
12 in. (30.5 cm)
12 in. (30.5 cm)
C
Dryer front clearance
Not Applicable
2 in. (5.1 cm)
D
Exhaust duct clearance to
2 in. (5.1 cm)
2 in. (5.1 cm)
combustible material
E
Weather hood to ground clearance
12 in. (30.5 cm)
12 in. (30.5 cm)
F
Distance from floor or ceiling to
Not Applicable
3 in. (7.6 cm)
hole edge
G*
Area of centered air openings in
Not Applicable
40 sq. in./open (260 sq. cm)
closet door
*Louvered
door with equivalent
air openings
is acceptable.
(Minimum
clearances
are shown.)
**NOTE: For new installations,
locate top of wall vent 42 inches (106.7 cm) above floor to make venting easier to
connect.
1
Closet Door
2
Centered Air Openings (2 openings minimum)
3
Outer Wall of Enclosure
Figure 19
24
© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
512023