Installation
Heat Source Check
Electric
Dryers
Close the loading door and start the dryer in a heat
setting (refer to the Operating
Instructions
supplied
with the dryer). After the dryer has operated
for three
minutes, the exhaust
air or exhaust pipe should be
warm.
Gas Dryers
To view the burner flame, remove the lower front
panel of the dryer.
Close the loading door, start the dryer in a heat setting
(refer to the Operating
Instructions
supplied
with the
dryer); the dryer will start, the igniter will glow red
and the main burner will ignite.
IMPORTANT:
If all air is not purged
out of gas
line, gas igniter
may go off before gas is ignited.
If
this happens,
after approximately
two minutes
igniter will again attempt gas ignition.
After the dryer has operated
for approximately
five
minutes, observe burner flame through lower front
panel. Adjust the air shutter to obtain a soft, uniform
blue flame. (A lazy, yellow-tipped
flame indicates
lack
of air. A harsh, roaring, very blue flame indicates
too
much air.) Adjust the air shutter as follows:
1. Loosen the air shutter lockscrew.
.
.
Turn the air shutter to the left to get a luminous
yellow-tipped
flame, then turn it back slowly to
the right to obtain a steady, soft blue flame.
After the air shutter is adjusted
for proper flame,
tighten the air shutter lockscrew
securely.
4. Reinstall
the lower front panel.
WARNING
For personal
safety, lower front panel must
be in place during
normal operation.
W046
After the dryer has operated
for approximately
three
minutes, exhaust
air or exhaust pipe should be warm.
1
2
3
4
Air Shutter Lockscrew
Appliance Main Gas Valve
Air Shutter
0.125 in. (3.1 mm) Pipe Plug
(For checking manifold pressure)
D7001
Figure 9
12