Installation
Step 3: (Gas Dryer Only) Connect
Gas
Supply
Pipe
For further assistance,
refer to section on Gas
Requirements.
.
.
Make certain your dryer is equipped
for use with
the type of gas in your laundry room. Dryer is
equipped
at the factory for Natural
Gas with a
0.375 inch NPT gas connection.
Remove the shipping
cap from the gas
connection
at the rear of the dryer. Make sure you
do not damage the pipe threads when removing
the cap.
.
4.
.
Connect to gas supply pipe.
Tighten all connections
securely. Turn on gas and
check all pipe connections
(internal and external)
for gas leaks with a non-corrosive
leak detection
fluid.
For L.R (Liquefied
Petroleum)
gas connection,
refer to section on Gas Requirements.
2
3
2
3
4
New Stainless Steel Flexible Connector -
Use only if allowed by local codes
(Use Design CSA Certified Connector)
0.125 in. NPT Pipe Plug
(For checking inlet gas pressure)
Equipment Shut-Off Valve - Install within
6 ft. (1.8 m) of dryer
Black Iron Pipe
Shorter than 20 ft. (6.1 m) - Use 0.375 in.
(9.5 mm) pipe
Longer than 20 ft. (6.1 m) - Use 0.5 in.
(12.7 mm) pipe
0.375 in. NPT Gas Connection
Figure 5
D2331
10