Installation
Manufactured (Mobile) Home
Installation
IMPORTANT:
Installation
must conform
to 1
the Manufactured
Home Construction
and
1
Safety Standards,
Title 24 CFR, Part 32-80
|
Standard
CAN/CSA-Z240
The dryer can be installed
in a manufactured
(mobile)
home by following
these instructions:
.
IMPORTANT:
Gas dryers MUST be
permanently
attached
to the floor at the time
of installation.
Order No. 526P3 Dryer
Installation
Kit for a manufactured
(mobile)
home installation.
Follow the instructions
supplied
with the kit.
2. Venting - Dryer MUST be exhausted
to the
outdoors.
WARNING
To reduce
the risk of fire and combustion
gas accumulation,
the dryer MUST
BE
EXHAUSTED
TO THE OUTDOORS.
Refer to
Section
on Dryer Exhaust
Requirements.
W047
The dryer can be exhausted
to the outdoors
through the back, left, right or bottom panel. Gas
dryers cannot be exhausted
out the left side
because of the burner housing.
The dryer exhaust duct must be secured to the
mobile home structure.
Exhaust ducts MUST NOT be connected
with
sheet metal screws or fasteners
which extend into
the duct.
Exhaust duct must not be connected
to any other
duct, vent or chimney.
Dryer exhaust
duct MUST NOT terminate
under
the mobile home.
For proper operation,
it is important that the dryer
has an ample amount of outside make-up
air. The
free area of any opening for the introduction
of
outside air must be at least 25 in 2 (163 cm2).
When exhausting
the dryer to the outdoors,
the
dryer can be installed
with "0" inch clearance
at
the sides and rear. Clearance
of the duct from
combustible
construction
must be a minimum
of
2 inches (5.08 cm).
Venting materials
are not supplied with the dryer
(obtain locally).
WARNING
To reduce
the risk of fire, the exhaust
duct
and weather
hood MUST be fabricated
of a
material
that will not support
combustion.
Rigid or flexible
metal pipe is
recommended
for a clothes
dryer.
W048
14
© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
512023