12. Maintenance
•
Grease the boiler and tank cap opening as well as the O-rings on the tank nozzle and
pressure relief valve if necessary. (Fig. 11)
•
Check the lter in the tank cap and clean it if necessary.
13. Important Note regarding Product Liability!
In accordance with an EC directive, the manufacturer is liable for this product only if all parts
originate from or were approved by the manufacturer and the tools are assembled and
operated correctly. The use of other accessories and spare parts can partially or completely
invalidate the liability.
14. Correction of Malfunctions
Malfunction
Malfunction
The steam
wallpaper
stripper is not
working
Water in or
under the
device
26
Cause
Cause
•
Heating element covered in
limescale
•
Malfunction (Descale and Re ll
ash and an acoustic signal
sounds)
•
Too little water in tank. A safety cut
out is tted to prevent overheating
of element if there is little water in
tank.
•
Unit at an angle, heating element is
not in water.
•
Usage of an extension lead
•
Overpressure valve triggered (e.g.
due to calci cation or kinked/
clogged hose)
•
Overpressure valve triggered (e.g.
due to calci cation or kinked/
clogged hose)
•
Boiler leaking
SteamForce Speed Pro
Remedy
Remedy
•
Clean
•
Check the unit (tank, hose)
for leaks. Check if the oat
is stuck. Check the heating
element for scale build-up.
Check / clean the lter in
the tank cap.
•
Check the heating element
and descale if necessary.
Fill with more water. Wait 2
minutes. Re ll will reset the
cut-out element.
•
Move unit into horizontal
position.
•
Check that the extension
lead is rated at minimum of
13 Amps (230V)/ 16 Amps
(110V) and fully unwound.
•
Let the device cool down
and eliminate the cause (e.g.
descale and clean hose)
•
Let the device cool down
and eliminate the cause (e.g.
descale and clean hose)
•
Replace