Optimising the detection
distance
• If flushes are actuated too soon, too late
or unintentionally, you can optimise the
detection distance of the IR sensor. For
this, you must remeasure the detection
range.
• You must optimise the detection distance
within the first 30 minutes after activating
the power supply.
Prerequisite
Refer to illustration sequence
page 45 while carrying out the
instructions.
1
Restart the urinal flush control. →
See "Restarting the urinal flush
control", page 13.
✓ The urinal flush control restarts.
2
Hold a white sheet of paper in front
of the IR sensor on the bottom edge
of the urinal ceramic appliance.
✓ 2 short signal tones will sound
after 2 seconds.
3
Keep the white sheet of paper in
front of the IR sensor for a further
15 seconds.
4
Remove the white sheet as soon as
a signal tone sounds every second.
5
Step away from the urinal for at least
10 seconds so that the detection
range can be remeasured.
Result
✓ Once the procedure has been
completed, the flush will be actuated
and the detection distance will be set.
The urinal is ready for operation.
12
All manuals and user guides at all-guides.com
8
,
Replacing the batteries
Prerequisite
Refer to illustration sequence
page 47 while carrying out the
instructions.
2 replacement batteries (alkaline
batteries, 1.5 V, AA) are available.
1
Demount the urinal flush control. →
See illustration sequence
page 39.
2
Disconnect the battery compartment
cable. → See illustration sequence
9
, page 46.
3
Remove the battery compartment.
4
Open the cover, remove the
batteries and dispose of them.
5
Insert the replacement batteries.
6
Insert the battery compartment.
7
Plug in the battery compartment
cable. → See illustration sequence
10
, page 46.
8
Mount the urinal flush control. →
See illustration sequence
page 40.
Result
✓ The urinal is ready for operation.
11
,
2
,
3
,
7021420811-1 © 01-2020
969.653.00.0(00)