Replacing the urinal trap
For hygiene reasons, replace the urinal trap
at least once a year.
Prerequisite
Cleaning mode is activated.
Refer to illustration sequence
page 42 while carrying out the
instructions.
1
Demount the cover for the urinal
trap.
2
Demount the urinal trap.
3
Replace the urinal trap (art. no.
243.312.00.1) and the cover for the
urinal trap (art. no. 243.314.00.1).
4
Mount the urinal trap.
5
Mount the cover for the urinal trap.
10
All manuals and user guides at all-guides.com
5
,
Cleaning or replacing the
basket filter
• Clean the basket filter in the solenoid
valve at least every 2 years or if the flush
volume decreases.
• Descale the basket filter with a commer-
cially available descaling agent if
necessary.
• Replace the basket filter if it can no
longer be completely cleaned and
descaled.
Prerequisite
Refer to illustration sequence
page 43 while carrying out the
instructions.
1
Demount the urinal flush control. →
See illustration sequence
page 39.
2
Disconnect the cable for the battery
or rechargeable battery
compartment. → See illustration
sequence
9
, page 46.
3
Demount the locking bracket.
4
Disconnect the solenoid valve and
demount the coupling.
5
Remove the basket filter.
6
Clean, descale or replace the basket
filter.
7
Install the basket filter.
8
Mount the coupling and snap in the
solenoid valve.
9
Mount the locking bracket.
6
,
2
,
7021420811-1 © 01-2020
969.653.00.0(00)

Publicité