Outside Back Exhaust (Example Only)
The following chart describes an example of one possible
ductwork installation.
Duct
Equivalent Length x
Description
Pieces
Number Used =
40 Ft. (12.2m) x
Wall Cap
(1)
3 Ft. Straight
Duct
3 Ft. (0.9m) x
(31/4" x 10"/8.2
(1)
x 25.4cm
Rectangular)
10 Ft. (3m) x
90° Elbow
(2)
Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good
venting performance with any vent hood.
NOTE: For back exhaust, care should be taken to align
exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between
the wall studs to accommodate exhaust.
Installation Types (Choose A, B or
C)
This microwave oven is designed for adaptation to the
following three types of ventilation:
A. Recirculating (Non-Vented Ductless)
B. Outside Top Exhaust (Vertical Duct)
C. Outside Back Exhaust (Horizontal Duct)
NOTE: This microwave is shipped assembled for
Recirculating. Select the type of ventilation required for your
installation and proceed to that section.
A. Recirculating (Non-Vented Ductless)
B. Outside Top Exhaust (Vertical Duct)
C. Outside Back Exhaust (Horizontal Duct)
CCD-0006072 Rev: 11-15-23
Equivalent
Duct Pieces
40 Ft.
=
(12.2m)
3 Ft.
=
(0.9m)
20 Ft.
=
(6.1m)
63 Ft.
Total Length
=
(19.2m)
Adaptor in Place for
OutsideTop Exhaust
Remarks
A. Recirculating (Non-Vented
Ductless)
Installation Overview
NOTE: Cabinet depth maximum in exhaust mode is 141/2"
(37cm).
A1: Attach the Mounting Plate to the Wall
A2: Use Top Cabinet Template for Preparation of Top Cabinet
A3: Check Blower Plate
A4: Mount the Microwave Oven
A5: Installing or Change the Charcoal Filter (Some Models)
IMPORTANT NOTES:
●
Make sure the screws for the blower motor and blower
plate are securely tightened when they are reinstalled. This
will help to prevent excessive vibration.
●
Make sure the motor wiring has been properly routed and
secured, and that the wires are not pinched.
A1: Attach the Mounting Plate to the
Wall
Attach the plate to the wall using toggle bolts (and wing nuts)
(3/16" X 3"). At least one wood screw must be used to attach the
mounting plate to a wall stud.
- 7 -
Adaptor Must Be
Moved to the Back for
Outside Back Exhaust