4. Slide the top of the new charcoal filter into the top of the
filter cavity.
5. Press the bottom of charcoal filter to place it into the
correct position..
6. Reinstall the vent by sliding the bottom of the vent into
place. Push the vent top into position and slide right into
place. Replace the two vent mounting screws located on
top of the microwave using a #1 Phillips screwdriver.
7.
Close the microwave door. Plug in microwave oven or
reconnect power.
B. Outside Top Exhaust (Vertical
Duct)
Installation Overview
NOTE: Cabinet depth maximum in exhaust mode is 141/2"
(37cm).
B1: Attach the Mounting Plate to the Wall
B2: Use Top Cabinet Template for Preparation of Top Cabinet
B3: Adapting Blower for Outside Top Exhaust (Vertical Duct)
B4: Check for Proper Damper Operation
B5: Mount the Microwave Oven
B6: Adjust The Exhaust Adapter
B7: Connecting Ductwork
IMPORTANT NOTES:
●
Make sure the screws for the blower motor and blower
plate are securely tightened when they are reinstalled. This
will help to prevent excessive vibration.
●
Make sure the motor wiring has been properly routed and
secured, and that the wires are not pinched.
B1: Attach the Mounting Plate to the
Wall
Attach the plate to the wall using toggle bolts (and
wing nuts) (3/16" X 3"). At least one wood screw must
be used to attach the mounting plate to a wall stud.
1.
Remove the toggle wings from the bolts.
2. Insert the bolts into the mounting plate through the holes
designated to go into drywall and reattach the toggle
wings to 3/4" (19mm) onto each bolt.
3. Place the mounting plate against the wall and insert the
toggle wings into the holes in the wall to mount the plate.
NOTE: Before tightening toggle bolts and wood screw, make
sure the bottom of the mounting plate touch the bottom of the
- 10 -
CCD-0006072 Rev: 11-15-23