B.Ventilating your room
Press MODE button repeatedly until the FAN indicator lights up.
In ventilation mode, the room air is circulated, but not cooled.
Press SPEED button repeatedly to select the fan speed as desired.
C.Drying your room
Press MODE button on the control panel or remote control, the dry
indicator lights up. The fan speed is unable to select. User should
connect the hose to the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and
cannot be selected.
D.Sleep mode
The sleep mode can be activated when in cool mode.
In cool mode:
After 1 hour the preset temperature is increased by 1 ℃, after
another hour the preset temperature will again be increased by 1 ℃.
5.3.3 TIMER SETTING (1hour-24hours) :
The timer has two ways of operation:
Press Timer key to
To turn off
turn on the timer
(When power on)
function.
Press Timer key to
To turn off
turn on the timer
(When power on)
function.
Press Up /Down repeatedly until the LED
Cancel timer
shows '00'.
Note: when press POWER, the unit will also
exit the timer setting.
5.3.4 Automatic Defrost
At low room temperatures, frost may buildup at the evaporator
during operation. The unit will automatically start defrosting and the
POWER indicator will flash. The defrost control sequence is as
follows:
14
A.When the unit operates in the cooling operation, drying operation,
the ambient temperature sensor senses that the evaporator coil
temperature is below -1°C. And when the compressor stops
operating for 10 minutes or the coil temperature up to 7℃, the unit
will restart to cool operating mode.
B.When the unit operates in the drying operation, once the coil
temperature sensor senses the temperature of the evaporator is
below 40℃ and the differential temperature between coil temperature
and room temperature is below 19℃ after the compressor operation
for 20minutes, the unit start defrosting for 5 minutes and the power
indicator blinking.
5.3.5 Overload Protection
In the event of a power loss, to protect the compressor, there is a
3-minute delay until the compressor restarts.
5.4 DRAINAGE
Self- evaporating system
The self-evaporating system uses the collected water to cool the
condenser coils for better efficient performance. There is no need to
empty the drainage tank in cooling operation, except in drying
operation and high humidity conditions. The condensate water
Press Up /Down
evaporates at the condenser and is evacuated through the exhaust
repeatedly to set the
hose.
delay OFF time.
For continuous operation or unattended operating in drying operation,
please connect the attached drain hose to the unit. Condensate water
Press Up /Down
will automatically flow into a bucket or drain by gravity.
repeatedly to set the
delay ON time.
● Switch off the unit before operating.
● Remove the plug of the water outlet opening,
and keep it in safe area.
● Securely and properly connect the drain hose
and make sure that it is not kinked and clear of
obstruction.
● Place the outlet of hose over a drain or bucket
and ensure that water could freely flow out of
the unit.
Do not submerge the end of hose into water;
otherwise it can cause "Air Lock" in the hose.
To avoid water spillage:
● As the negative pressure of condensate drain pan is large, tilt the drain
hose downward toward the floor. It is appropriate that the degree of
inclination should exceed 20 degrees.
● Straighten the hose to avoid a trap existing in the hose.
EN
Remove the rubber
sealing plug.
Continuous drain hose.
15