Télécharger Imprimer la page

Nussbaum HF 3S 3000 Manuel D'exploitation page 90

Publicité

Made
in
Germany
1
2
4
3
Figure 21: General assembly view without riser extension
1 Cross-beam
2 Operating column
3 Long lifting arm
4 Operating unit
A foundation must be made according to the „Foundation
plan" sheet regulations. Also a level, set up surface must be
ensured for the lift so there is continuous contact between
the lift and the concrete floor.
1 Column
2 Base plate
3 Safety anchor
• To reach a higher level of protection against humidity
from the workshop floor, a thin PE foil should be put be-
tween the workshop floor and column base plate before
anchors are placed. Also, the gap between the base
plate and workshop floor should be silicone sprayed
after anchoring.
• Lift the cross-beam that is fastened to a column and fas-
ten to the opposite side. Hydraulic lines are marked in
90
5
6
7
5 Riser
6 Counter column
7 Short lifting arm
Figure 22: Anchoring
OPI-POWER LIFT HF 3S 3000-4000_V4.2_DE-EN-FR-ES-IT – Teile-Nr: 0006255
colours thereby making them easy to connect.
• Holes for floor anchoring are to be placed through the
holes in the base plates.
Clean the bore holes by blowing them out with air. In-
sert safety anchors into the holes.
The manufacturer recommends e.g. Hilt injection an-
chors or similar anchors from other manufacturers, with
approval and in compliance with their specifications.
Before anchoring the lift, check whether the concrete is
of quality C20/25 up to the finishing level of the com-
pleted floor. In this case, determine the anchor length
from the "Selection of anchor length without floor cover-
ing (in appendix) data sheet. If there is a floor covering
(tiles, screed) on the weight bearing concrete, the thick-
ness of this covering must be determined. Afterwards,
then determine the anchor length from the "Selection
of anchor length without floor covering (in appendix)
data sheet.
• Position and align the lift and lift columns using a bub-
ble level.
• The base plates are also to be supported with suitable
underlays (thin metal strips) to ensure precise vertical set
up and contact between the base plate and the floor.
• Tighten the anchors using a torque wrench.
Each anchor must be able to be tightened
!
to the torque specified by the manufacturer.
Safe operation of the lift is not guaranteed
with a lower torque.
• If an anchor is tightened to the specified torque, then
the domed washer lays flat on the base plate. Secure
anchor connection is then guaranteed.

Publicité

loading

Ce manuel est également adapté pour:

Hf 3s 3500Hf 3s 4000