Before servicing, always release system pressure by following PRESSURE RELIEF PROCEDURE (page 30).
WARNING
PROBLEM
A. The sprayer does not start. 1) Battery flat, faulty or incompatible
B. The sprayer starts but does
not draw in paint.
C. The sprayer draws up
paint but the pressure
drops when the gun is
triggered.
D The sprayer has switched
off during operation
(indicator light flashes)
E. The PRIME/SPRAY valve is
on SPRAY and there is flow
through the return tube.
F. The spray gun leaks.
G. The tip assembly leaks.
H. The spray gun will not
spray.
I. The paint pattern is tailing.
J. Spray jet is uneven/
pulsating
CAUSE
2) The ON/OFF switch is set to OFF.
3) The sprayer shuts off while still under
pressure.
4) There is a problem with the motor.
1) The unit is not primed.
2) The hopper is empty.
3) The inlet filter is clogged.
4) The inlet or outlet valve is stuck.
5) The inlet valve is worn or damaged.
6) The PRIME/SPRAY valve is plugged.
1) The spray tip is worn.
2) The inlet filter is clogged.
3) The gun or spray tip filter is plugged.
4) The paint is too heavy or coarse.
5) The outlet valve assembly is dirty or worn.
6) The inlet valve assembly is damaged or
worn.
1) Device overloaded / motor overheated
1) The PRIME/SPRAY valve is dirty or worn.
1) Internal parts of the gun are worn or dirty. 1) Replace the spray gun with a new one.
1) The tip was assembled incorrectly.
2) A seal is worn.
1) The spray tip or the gun filter is plugged.
2) The spray tip is in the CLEAN position.
3) PRIME/SPRAY knob not set on SPRAY.
1) The gun, the tip, or the inlet filter is plugged.
2) The tip is worn.
3) The paint is too thick.
4) Pressure loss.
1) Pulsation damper faulty
TROUBLESHOOTING
SOLUTION
1) Charge or replace
2) Turn the ON/OFF switch to ON.
3) Motor will cycle ON and OFF while spraying as it needs
pressure. This is normal. Resume painting.
4) Take sprayer to Wagner Authorized Service Center.
1) Set the device to PRIME and switch it on until paint flows
out of the return pipe hose.
2) Refill the hopper. Set the device to PRIME and switch it on
until paint flows out of the return pipe hose.
3) Clean the inlet filter.
4) Clean the inlet and outlet valves and replace any worn parts.
Inlet may be stuck from old paint. Push inlet filter tab to
release.
5) Replace the inlet valve.
6) Take sprayer to Wagner Authorized Service Center.
1) Replace the spray tip with a new tip.
2) Clean the inlet filter.
3) Clean or replace the proper filter. Always keep extra filters
on hand.
4) Thin or strain the paint.
5) Clean or replace the outlet valve assembly.
6) Replace the inlet valve.
1) Switch off the appliance, depressurise and allow to cool
down. If the problem persists, contact Wagner Service.
1) Take sprayer to Wagner Authorized Service Center.
1) Check the tip assembly and assemble properly.
2) Replace the seal.
1) Clean the spray tip or gun filter. Review Unclogging the
Spray Tip.
2) Put the tip in the SPRAY position.
3) Turn the PRIME/SPRAY knob to SPRAY.
1) Clean the filters and strain the paint.
2) Replace the spray tip.
3) Thin the paint.
4) Refer to Causes and Solutions for problem C.
1) Replace pulsation damper (see Maintenance chapter)
EN